While further developing the conventional radiation protective shield, a completely new concept was born at MAVIG to minimize radiation exposure to the examiner and his assistance. Optimized for the use during radial and femoral access it leads to a significant improvement in radiation protection by a factor of 10, if the shield is used in combination with our radiation protective drapes.
Elimination of Underpassing Radiation
The underpassing radiation results from the scattered radiation originating in the patient volume radiographed, a considerable proportion of which travels through the patient’s body tissue. The examiner is thus exposed to the scattered radiation that has traveled underneath the shield and then exited the patient’s body. The flexible panel curtain lays perfectly flush to the patient’s body when the protective shield is positioned and stops a significant proportion of the scattered radiation coming from the patient’s body. At the same time the gap between the shield and the surface of the patient‘s body is closed.
Ideal for Femoral and Radial Artery Access
The new radiation protective shield has two curved cut-outs. The large cutout follows the contour of the patient’s body, and a second smaller cutout allows for the patient’s arm to be placed underneath it. To provide the best possible protection during procedures using the femoral artery, the overlapping panels ensure that the arm cutout, which is not in use, remains completely closed. For procedures using the radial artery, the panels spread out so that the puncture site is exposed but the curtain does not offer any gaps through which scattered radiation might reach the examiner.
Increased Freedom of Movement and Enlarged Protective Zone
By making the area of protection higher, even examiners up to 195 cm (6’4) tall are very well protected. The increased width and the resultant increase in the radiation shadow mean that changes in the examiner’s position do not increase the exposure dose.
The extension / spring arm combination Portegra2 offers a large range of different load bearing categories:
Scope of Delivery: Radiation Protective Shield with Curtain, Portegra2 Extension and Spring Arm, 1 Box of Sterile Covers STEA-OT4.
Sterile Covers
The compatibility with existing Portegra2 ceiling systems ensures an uncomplicated integration and installation and avoids large room planning actions. In just a few steps, you and your personnel are well protected and improve your working conditions.
Compatible with:
Are you interested in the retrofit kit OT94001I? Please send us a nonbinding request for a quote.